R-128

Radial Sideshots

Survey Radial Sideshots

.

The Radial Sideshots routine combines the functionality of the

Multiple Sideshots routine with the accuracy of the Repetition Shots

routine. It is used to perform repetition shots to a backsight and any
number of foresights (side shots) from the same occupy point.
The routine consists of multiple screens. Each is customized

according to where you are in the routine. Consult the User's manual
for more information on using this routine.

: accesses the Surveying Settings screen (Page R-44)

and Radial Sideshot Settings screen, which is identical to

the Repetition Settings screen (Page R-51) with the

exception of the choices for the Shooting Sequence.
Select B>F1>..>Fn^F1>..>Fn>B to shoot all Face 2 side
shots in the same order as the Face 1 side shots, or
B>F1>..>Fn^Fn>..>F1>B

to shoot the Face 2 side shots in

reverse order.
Option: When shooting the first set, measuring a
distance and angle for each shot is required, but when

starting all subsequent sets, Angle Only can also be
selected for this field.
Number of Sets: is where the desired number of sets is
specified.

Done with SS > : is used when you are finished shooting side shots.

This is only available while taking Face 1 side shots for the first set.

Shoot / Shoot BS : is used to shoot the current point. If the shot

was already performed, the Next > button will be enabled. Tapping

Shoot again will throw out the results of the last shot and re-shoot it.

Next > : is used to take the next required shot in the routine. The

button label will contain additional information to help indicate