Sample output, Systems – Avaya P580 User Manual
Page 729

Document No. 10-300090, Issue 1
32-33
User Interface
Sample Output
The following example creates the username boston with a password of
mass and an access-type of admin:
#
username boston password mass access-type admin
Systems
P580 and P882.
[access-type
{read-only | read-
write | admin |
The access type for the user. Options are:
• read-only
• read-write
• admin
•
The
type to the user. For information about custom access
types, see Chapter 2, “Setting Up the Switch,” in the
User Guide for the Avaya P580 and P882
Multiservice Switches, Software Version 6.1.
The default access type is read-only.
[mgmt-type [all]
[local-cli]
[remote-cli]
[web]]
The management interfaces to which you want the user to
have access. Options are:
• all—All management interfaces.
• local-cli—CLI on the PC that is connected to the
serial port on the supervisor module.
• remote-cli—CLI by means of a Telnet connection.
• web—Web Agent.
The default setting is all.
Number of weeks for which the user account is valid. The
expiration period can range from 3 to 999 weeks. The
default setting is 0, no expiration.
When a user account expires, you must reset the account.
Use the username
command to reset the account.
Number of weeks before user account expiration that you
want the user warned. The expiration warning can range
from 0 to the expiration period. A setting of 0 indicates that
no warning is generated.
enable
Enables the user account.
disable
Disables the user account.
Table 32-17. Parameters, Keywords, Arguments
Name
Definition
2 of 2