Set port internal-error-shutdown, Command mode, Description – Avaya P580 User Manual
Page 452: Syntax, Sample output, Systems, Set port internal-error-shutdown -20

Chapter 21
21-20
Command Reference Guide for the Avaya P580 and P882 Multiservice Switches, v6.1
set port internal-error-shutdown
Command Mode
Global Configuration.
Description
Sets switch ports to shutdown if their rate of internal errors exceeds the
threshold setting. To set the threshold, use the set-internal-error-threshold
command. For information on this and other IEDR commands, see
, “
Syntax
Sample Output
The following example enables IEDR on all ports on the module in slot 3.
(configure)#
set port internal-error-shutdown 3 enable
Systems
P550R, P580, P880, and P882.
To Enable:
set port internal-error-shutdown {
To Disable:
set port internal-error-shutdown {{
Table 21-18. Parameters, Keywords, Argument
Name
Definition
{
The slot number of the module, and, either port
number, or range of port numbers. Enter the port
ranges in the format Px-Py. For example:
• To specify port 1 on the module in slot 3, enter
3/1.
• To specify ports 1 through 5 on the module in
slot 3, enter 3/1-5.
all-ports
Enables or disables IEDR on all ports on all modules in
the switch.