Ip igmp query-interval, Command mode, Description – Avaya P580 User Manual
Page 133: Syntax, Sample output, Systems, Ip igmp query-interval -7
Document No. 10-300090, Issue 1
9-7
IGMP
ip igmp query-interval
Command Mode
Interface Configuration.
Description
Configures the frequency at which the router sends IGMP host-query
messages. The no form of this command restores the default value of 125
seconds.
Syntax
Sample Output
The following example configures the frequency at which the router sends
IGMP host query messages on interface labelled “boston” to 125 seconds.
(config-if:boston)#
ip igmp query-interval 125
Systems
P550R, P580, P880, and P882.
To Configure
ip igmp query-interval
To Restore Default:
[no] ip igmp query-interval
Table 9-3. Parameters, Keywords, Arguments
Name
Definition
The number of seconds between host-query messages. The valid
range is 1 to 65,535 seconds. The default setting is 125 seconds.