Irdp maxadvertinterval, Command mode, Description – Avaya P580 User Manual
Page 208: Syntax, Systems, Irdp maxadvertinterval -24
Chapter 11
11-24
Command Reference Guide for the Avaya P580 and P882 Multiservice Switches, v6.1
irdp maxadvertinterval
Command Mode
Interface Configuration.
Description
Sets the maximum interval in seconds between advertisements. The range is
4 to 1800 seconds. The default value is 600 seconds.
The no command restores the default setting.
Syntax
Systems
P550R, P580, P880, and P882.
To Configure:
ip irdp maxadvertinterval
To Restore Default:
no ip irdp maxadvertinterval
Table 11-12. Parameters, Keywords, Arguments
Name
Definition
Maximum interval in seconds between advertisements. The
range is 4 - 1800 seconds. The default value is 600 seconds.
This manual is related to the following products: