set port intrusion-trap-timer
Command Mode
Global Configuration.
Description
Sets the time interval at which intrusion traps are generated. The default
setting for the intrusion trap timer is 1800 seconds (30 minutes). The valid
range for the timer is 60 to 1800 seconds.
Syntax
set port intrusion-trap-timer {
[...,{
Systems
P550R, P580, P880, and P882.
Table 21-20. Parameters, Keywords, Arguments
Name
Definition
Specifies the number of the module.
Specifies a range of switch ports.
Time interval at which intrusion traps are generated.
The default setting for the intrusion trap timer is 1800
seconds (30 minutes). The valid range for the timer is 60 to
1800 seconds.