Set temperature (warning), Command mode, Description – Avaya P580 User Manual
Page 694: Syntax, Set temperature (warning) -4
Chapter 31
31-4
Command Reference Guide for the Avaya P580 and P882 Multiservice Switches, v6.1
set temperature (warning)
Command Mode
Global Configuration.
Description
Sets the warning temperature (in Celsius) for a specific component of the
switch. The default values are listed in
Syntax
set temperature {supervisor-slot | backplane-sensor | cpu-sensor | probe}
warning {upper | lower | low-limit}
Table 31-3. Default Warning Temperatures
Component
Upper
Warning
Lower
Warning
Low Limit
CPU Sensor
85°
5°
0°
All others
60°
5°
0°
Table 31-4. Parameters, Keywords, Arguments
Name
Definition
{supervisor-slot |
backplane-sensor |
cpu-sensor | probe}
Indicates which component of the switch you are setting
the temperature for.
Note:
After you change the temperature settings for the
active supervisor, you must synchronize the active
and standby supervisors to copy the temperature
settings to the standby supervisor.
warning
Required parameter indicating that a warning limit is
being modified.
1 of 2