Sample output, Systems – Avaya P580 User Manual
Page 695

Document No. 10-300090, Issue 1
31-5
Temperatures
Sample Output
The following example sets the backplane-sensor upper warning
temperature to 44° (Celsius).
(configure)#
set temperature backplane-sensor warning upper 44
Systems
P550R, P580, P880, and P882.
{upper | lower |
low-limit}
Indicates warning being changed.
Upper warning:
• Backplane is 5 to 65 degrees
• CPU is 5 to 100 degrees
• Supervisor Module is 5 to 65 degrees.
Lower warning:
• Backplane is -128 to 5 degrees
• CPU is degrees 0 to 100
• Supervisor Module is 0 to 65 degrees.
Low- limit:
• Backplane is -128 to +5 degrees
• CPU is -128 to +100 degrees
• Supervisor Module is -128 to +65 degrees.
Temperature in degrees Celsius for the warning.
Table 31-4. Parameters, Keywords, Arguments
Name
Definition
2 of 2