Status Response Generator Example

191

Figure 172. Switching Between ASCII and Hex Entry Modes

2.

Define the output that should be transmitted to the host.

In the Output field, press the down arrow key and type 15 (NAK).

See Figure 172.

NOTE:

Use the up and down arrow keys to switch between the ASCII and
Hex entry modes.

3.

Under Status Bits, click

Job In Process

to select the correct condition to

test.

Here is a description of the Status Bits conditions:

Unconditional:

This condition is always TRUE. The response is sent to

the host immediately.

Job Complete:

This condition is TRUE if the printer is not processing or

printing any data. The response is sent to the host immediately but ONLY
IF this condition is TRUE.

Job In Process:

This condition is TRUE if the printer is processing or

printing data. The response is sent to the host immediately but ONLY IF
this condition is TRUE.

Wait For Job Complete:

This condition is TRUE if the printer is not

processing or printing any data. The response is sent to the host AS
SOON AS this condition is TRUE.

4.

Click

Add

to add the entry to the list of protocol conditions.

Now you will add a second condition.

5.

In the Name field, type job_done.

6.

In the Output field, press the down arrow key and type 06 (ACK).

7.

Under Status Bits, click

Job Complete

.