Attributes
167
Ignore Case
Allows the matching of characters to be case independent. Whether the
character is “X” or “x” a match occurs.
Parameter
Allows characters in the incoming datastream to have a “label.” You can use
this label in the outgoing datastream to move characters to other locations
without changing them. If the outgoing datastream has no label specified,
then the character is removed from the incoming datastream.
Before/After
Specifies where the data is inserted.
Start/End
Starts and stops data flushing (activates and deactivates the datastream
adapter). Any data in the Output field passes to the printer instead of being
flushed.
Count
Specifies a fixed number of characters that are flushed following the Count
attribute (deactivates the datastream adapter). The fixed number is specified
in the Count field.
Flush
Removes the input string from the datastream, preventing it from being
printed.
Include
Specifies that the character that has the attribute will be included in the Store
mode operation.
Insert Pattern
Allows a defined pattern to be inserted in the CST. See “Patterns / Variables”
on page 170.
Insert Variable
Allows a defined variable to be inserted in the CST. See “Patterns / Variables”
on page 170.