beautypg.com

Table 80 ethernet port configuration: port setup – ZyXEL Communications Version 1.03 User Manual

Page 164

background image

Chapter 16 Ethernet Port Configuration

NetAtlas Workgroup User’s Guide

164

The following table describes the fields in this screen.

Table 80 Ethernet Port Configuration: Port Setup

LABEL

DESCRIPTION

Active

Select this check box to enable a port. The factory default for all ports is enabled. A

port must be enabled for data transmission to occur.

Type

This field displays the port type and port speed.

Port Name

Enter a descriptive name for identification purposes.

Speed/

Duplex

Select the speed and the duplex mode of the Ethernet connection on this port. Choices

are Auto, 10M/Half Duplex, 10M/Full Duplex, 100M/Half Duplex, 100M/Full Duplex

and 1000M/Full Duplex (for Gigabit/mini-GBIC ports only).
Selecting Auto (auto-negotiation) makes one Ethernet port able to negotiate with a

peer automatically to obtain the connection speed and duplex mode that both ends

support. When auto-negotiation is turned on, an Ethernet port on the switch negotiates

with the peer automatically to determine the connection speed and duplex mode. If the

peer Ethernet port does not support auto-negotiation or turns off this feature, the

switch determines the connection speed by detecting the signal on the cable and using

half duplex mode. When the switch’s auto-negotiation is turned off, an Ethernet port

uses the pre-configured speed and duplex mode when making a connection, thus

requiring you to make sure that the settings of the peer Ethernet port are the same in

order to connect.

Flow Control

A concentration of traffic on a port decreases port bandwidth and overflows buffer

memory causing packet discards and frame losses. Flow Control is used to regulate

transmission of signals to match the bandwidth of the receiving port. The switch uses

IEEE 802.3x flow control in full duplex mode and backpressure flow control in half

duplex mode.
IEEE 802.3x flow control is used in full duplex mode to send a pause signal to the

sending port, causing it to temporarily stop sending signals when the receiving port

memory buffers fill. Back Pressure flow control is typically used in half duplex mode to

send a "collision" signal to the sending port (mimicking a state of packet collision)

causing the sending port to temporarily stop sending signals and resend later. Select

Flow Control to enable it.

802.1p

Priority

The switch uses this priority value for incoming frames without an IEEE 802.1p priority

queue tag. The switch uses this priority value internally and does not add an IEEE

802.1p priority tag.

Intrusion Lock Select the Intrusion Lock check box to enable this security feature on a selected port

on the switch. If an Ethernet cable is disconnected from the port, intrusion locking

prevents access once a cable is reconnected. This limits risk from unauthorized

access such as hacking.

Note: You cannot access a port with intrusion locking enabled after a

cable is disconnected and then reconnected. You must clear
and re-select the Intrusion Lock check box to allow access to
the port again.

BPDU

Control

Configure the way to treat BPDUs received on this port. You must activate bridging

control protocol transparency in the Switch Setup screen first.
Select Peer to process any BPDU (Bridge Protocol Data Units) received on this port.
Select Tunnel to forward BPDUs received on this port.
Select Discard to drop any BPDU received on this port.
Select Network to process a BPDU with no VLAN tag and forward a tagged BPDU.