1 remote management limitations, Table 127 menu 24.11 – remote management control – ZyXEL Communications G.SHDSL.bis 4-port Security Gateway P-793H User Manual
Page 347

P-793H User’s Guide
Chapter 35 Menus 24.8 to 24.11
347
The following table describes the fields in this screen.
35.4.1 Remote Management Limitations
Remote management over LAN or WAN will not work when:
1 A filter in menu 3.1 (LAN) or in menu 11.5 (WAN) is applied to block a Telnet, FTP or
Web service.
2 You have disabled that service in menu 24.11.
3 The IP address in the Secure Client IP field (menu 24.11) does not match the client IP
address. If it does not match, the ZyXEL Device will disconnect the session immediately.
4 There is an SMT console session running.
5 There is already another remote management session with an equal or higher priority
running. You may only have one remote management session running at one time.
6 There is a firewall rule that blocks it.
Table 127 Menu 24.11 – Remote Management Control
FIELD
DESCRIPTION
TELNET Server
FTP Server
Web Server
Each of these read-only labels denotes a service that you may use to remotely
manage the ZyXEL Device.
Server Port
This field shows the port number for the service or protocol. You may change the
port number if needed, but you must use the same port number to access the
ZyXEL Device.
Server Access
Select the access interface (if any) by pressing [SPACE BAR], then [ENTER] to
choose from: LAN only, WAN only, ALL or Disable.
Secured Client IP The default 0.0.0.0 allows any client to use this service to remotely manage the
ZyXEL Device. Enter an IP address to restrict access to a client with a matching IP
address.
Once you have filled in this menu, press [ENTER] at the message "Press ENTER to Confirm or ESC to