6F8A0917

- 95 -

Checking the count rate and pulse width

How to check the count rate setting is shown below.
To check other setting values, select the following function numbers:

Pulse width mode

H2: PLS MODE

Pulse width

H3: PLS WIDTH

Switch operation

Display example

Description

H1: COUNT RATE
1.00000 m3

Select H1: COUNT RATE from the setting item selection
menu.
The currently set count rate appears.

H1: COUNT RATE

Returns to the menu of setting item selection.

Changing the count rate

The following is an example to change the count rate from 0.01m

3

to 200 l (liter).

Switch operation

Display example

Description

H1: COUNT RATE
1.00000 m3

Select H1: COUNT RATE from the setting item selection
menu.
The currently set count rate appears.

H1: COUNT RATE
1.00000 m3

The cursor appears.
Press

further to move the cursor to the digit of unit.

H1: COUNT RATE
1000.00 l

200.000 l

Change the unit to l.
Then press

to move the cursor to the desired digit to change

and change the number there. Repeat this operation until 200 l
appears on the display.

H1: COUNT RATE
200.000 l

The display blinks and the set value is displayed for

confirmation.

Press

MENU/ENT

again to write the data. Then the cursor

disappears and the display returns to the condition that the set

value is displayed.

H1: COUNT RATE

Returns to the menu of setting item selection.


Note: The indicting units for count rate are displayed cyclically as shown below.

m

3

ml

l

gal

bbl

pt

qt