beautypg.com

2 model number table – Toshiba Tohsiba Electromagnetic Flowmeter Converter L5232 User Manual

Page 170

background image

6F8A0917

- 169 -

15.2

Model Number Table

LF232*A, LF232*B Converter model number table

Model number

Specification code

1 2 3 4 5 6 7 8 9 10 11 12

Description

L

F 2 3 2 Separate

type

converter

Purpose

A

Standard

Compatible

detector

(Note

1)

(Note

2)

(Note

3)

A

Medium to small size (Meter size: 1/10” to 18”(2.5 to 450mm))

B Large

size

(Meter size 20” to 120” (500 to 3000mm))

Mounting nuts and bolts

C Panel,

wall

mounting

(BNP

material:

SUS304)

E

Pipe

mounting

(BNP

material:

SUS304)

Digital

input/output

1

Current output

+ Digital outputs points (1 point)

3

Current output

+ Digital outputs points (4 point) + Digital nputs points (2 point)

Communication

function

1 HART

communication

Power supply

1 100

to

240VAC,

50/60Hz

(Note

2)

2 24VDC

(Note

3)

A Standard

• Note 1: For applicable detector code, select one from the following table.

To combine with an existing detector, select one depending on the type of replaceable converters.
For combination with detectors not listed below, contact Toshiba.

Applicable
detector code

Applicable
detector

Applicable detector
(discontinued model)

Replaceable converters

A LF470

type

334,
335 type (Converters of
types shown right)

372, LF200, LF220,
LF420, LF230* A type

B LF150

type

337,
335 type (Converters of
types shown right)

373, 378, LF230* B type

• Note 2: When the 7th digit is “B” and power supply specification code is “1”, power supply specification

is 100 to 120VAC.

• Note 3: 24VDC can be specified only when the 7th digit is “A”.