beautypg.com

Toshiba Tohsiba Electromagnetic Flowmeter Converter L5232 User Manual

Page 138

background image

6F8A0917

- 137 -

(5) Single direction (external signal switching), 4 ranges

20mA

4mA

0

0

100

125

Output (%)

Range 4

Range 3

Range 2

Range 1

Reverse direction

Forward direction

Flow rate

External range switching
signal No. 1

External range switching
signal No. 2

L level input

H level input

H level input

H level input

L level input

L level input

(Range output No. 1)
(Range output No. 2)

ON

OFF

ON

ON

OFF

OFF

• Current output is 4mA as standard when fluid flows in reverse direction.

When the low cutoff function is not used (low cutoff setting is 0), it is possible to output the
current output signal in linear scale up to 3.2mA or 2.4mA when fluid flows in reverse direction.

• Works even if the range output is not used.