Toshiba Tohsiba Electromagnetic Flowmeter Converter L5232 User Manual
Page 43
6F8A0917
- 42 -
Notes on total flow value display
Note 1: The total flow value and the total difference flow value are displayed to the least
significant digit of the set count rate.
Example:
When the set count rate is 0.0001 m
3
Total flow / total difference flow display becomes
and the value
increases in increments of 0.0001 m
3
.
If the value reaches
, the display changes to
at the
next count.
In the end, the display becomes
.
When the set count rate is 10 m
3
The display becomes
and the value increases in increments of
10 m
3
.
Note 2: In the case of total difference flow display, if the forward direction total flow value or
reverse direction total flow value exceeds 9,999,999, only the total value that exceeded
9,999,999 will be reset to 0 and the count continues.
Example:
When the forward direction value returns to zero after it reaches the
maximum value
Forward direction:1000
Reverse direction:− 100
Flow difference: 900
→
Forward direction:
99999999
Reverse direction: − 100
Flow difference: 99999999
→
Forward direction: 0
Reverse direction:− 100
Flow difference: − 100
* In an example shown above, if the forward direction flow value is reset to zero
after reaching 99999999, flow difference indication changes from 99999899 to
−100 and the count continues.
(5) Percent display
Displayed to one decimal place (0.1%).
- 1 0 0 . 0 %
Up to 125.0% is displayed.
Flow direction: Forward direction “ ” (blank)
Reverse direction “
− ”
(6) Custom unit display
- 1 0 . 0 T E S T 1 2 3
Unit can be displayed up to 7 digits.
Value is indicated in 8 digits including a decimal point.
(Up to 9999999)
4 significant digits: m
3
/min value multiplied by the set
coefficient
Flow direction: Forward direction “ ” (blank)
Reverse direction ”
− ”