beautypg.com

Toshiba Tohsiba Electromagnetic Flowmeter Converter L5232 User Manual

Page 100

background image

6F8A0917

- 99 -

Checking the preset counter setting

How to check the preset count value is shown below.
To check the preset output function, select the function “I2: PRESET FNC.”

Switch operation

Display example

Description

I1: PRESET CNT
00000300

Select H1:PRESET from the setting item select menu.
The currently set preset count value appears.

I1: PRESET CNT

Returns to the menu of preset item selection.

Changing the preset count value

The following is an example to show how to change the preset value from 500 (count) to 1000
(count)

Switch operation

Display example

Description

I1: PRESET
00000500

Select I1:PRESET from the setting item selection menu.
The currently set preset count value (500 counts in this
example) appears.

I1: PRESET
00000500

The cursor appears.
Press

further to move the cursor to the desire digit to

change.

I1: PRESET
00001500
00001000

Change the number of the digit.
To change other digit, press

under this condition to move

the cursor to that digit and change the number there


I1: PRESET
00001000

The display blinks and the set value is displayed for

confirmation

Press

MENU/ENT

again to write the data. Then the cursor

disappears and the display returns to the condition the setting

value is displayed.

I1: PRESET

Returns to the menu of setting item selection.