4 wiring method, 1 terminal treatment of cables – Toshiba Tohsiba Electromagnetic Flowmeter Converter L5232 User Manual

Page 24

background image

6F8A0917

- 23 -

5.4 Wiring Method

Do not conduct wiring work when

power is

applied.

Do not work on piping and wiring

with wet

hands.

DON’T

Wiring while power is applied can
cause electric shock.

DON’T

Wet hands may result in electric
shock
.

5.4.1 Terminal Treatment of Cables

Proceed as follows to treat the terminals at the converter side of the flow rate signal and excitation
cable and to connect these cables to the terminal block. Use appropriate cables referring to 5.1
"Installation Cables." Attach and crimp a round type M4 insulated crimping terminal to the end of each
cable.

Excitation cable

Strip the sheath from the end of each wire as shown in Figure 5.2 and attach and crimp an M4
crimping terminal with insulated sleeve to the end of each wire and then connect the crimped
terminals to X and Y of the terminal block. Connect the terminal of red wire to E of the terminal
block.

X Black

E Red

Y White

M4 crimped terminal

25 to 45mm

Figure 5.2 Terminal Treatment of Excitation Cable