8.2.12 Display low cut On/Off
When the low output is cutoff by the setting in 8.2.10 “Low cutoff value,” whether the instantaneous
flow rate, flow velocity and % value should be set to zero or not can be selected.
Selection
Display low cutoff
1: ON
Display low cut is effective (On)
Display (instantaneous flow rate, flow velocity and %) will be set to
zero when the low output is cutoff.
2: OFF
Display low cut is not effective (Off)
Measured value will be output even if the low output is cutoff.
Checking whether the display low cut is On or Off
Proceed as follows to check whether the display low cut is On or Off.
Switch operation
Display example
Description
D4: DSP LOW CUT
2:OFF
Select D4: DSP LOW CUT from the setting item selection
menu.
The currently set display low cut On/Off status appears.
D4: DSP LOW CUT