15. Specifications

15.1

Specifications

Detector Combined Specifications

1. Measuring range: (measuring range in terms of flow velocity)

0 –1.0 ft/s to 0 – 32.8 ft/s (0 – 0.3 m/s to 0 –10 m/s)


For partially filled pipes detectors (Combined detector is LF502)

Meter Measurement

range

6” (150mm)

0 – 264 GPM(std) to 0 – 1320 GPM

(0 – 60 m

3

/h to 0 – 300 m

3

/h )

8” (200mm )

0 – 484 GPM(std) to 0 – 2420 GPM

(0 – 110 m

3

/h to 0 – 550 m

3

/h )

10” (250mm )

0 – 770 GPM(std) to 0 – 3850 GPM

(0 – 175 m

3

/h to 0 – 875 m

3

/h )

12” (300mm )

0 – 1100 GPM(std) to 0 – 5500 GPM

(0 – 250 m

3

/h to 0 – 1250 m

3

/h )

14” (350mm )

0 – 1540 GPM(std) to 0 – 7700 GPM

(0 – 350 m

3

/h to 0 – 1750 m

3

/h )

16” (400mm )

0 – 1980 GPM(std) to 0 – 9900 GPM

(0 – 450 m

3

/h to 0 – 2250 m

3

/h )

20” (500mm )

0 – 3124 GPM(std) to 0 – 15620 GPM

(0 – 710 m

3

/h to 0 – 3550 m

3

/h )

24” (600mm )

0 – 4400 GPM(std) to 0 – 22000 GPM

(0 – 1000 m

3

/h to 0 – 5000 m

3

/h )

(

Above flow rate is almost 0 – 3.28 ft/s (std) to 0 – 16.4 ft/s (0 – 1 m/s to 0 – 5 m/s ) flow velocity.

)