background image

6F8A0917

- 133 -

Output performance when multiple ranges are used

(1) Single direction (internal automatic switching), 4 ranges

20mA

4mA

0

0

100

125

Output (%)

Range output No. 1
Range output No. 2

ON

OFF

ON

OFF

ON

OFF

Range 4

Range 3

Range 2

Range 1

Hysteresis
(0 to 25%)

Reverse direction

Forward direction

Flow rate

• Current output is 4mA as standard when fluid flows in reverse direction.

When the low cutoff function is not used (low cutoff setting is 0), it is possible to output the
current output signal in linear scale up to 3.2mA or 2.4mA when fluid flows in reverse direction.