2 display format, Measured value display format – Toshiba Tohsiba Electromagnetic Flowmeter Converter L5232 User Manual
Page 41
6F8A0917
- 40 -
Note : There is not this screen to the converter before serial No.072320999.
( Menu screen is displayed. Menu lock cancellation screen is not displayed. )
Switch Basic
function
• Returns the screen from the parameter display screen to the menu display
screen.
• Returns the screen from the parameter input screen (Cursor ON) or
adjustment wait screen to the parameter display screen.
• Cancels the parameter input check screen (screen blinks) and returns to the
parameter input screen.
• If pressed while menu display screen is displayed, Function [MEAS MODE]
to return to the measurement mode appears.
(If MENU/ENT is pressed under that condition, the mode returns to the
measurement mode.)
7.2 Display Format
In the measurement mode, the measured data is displayed in the unit set by UNIT 1 and UNIT 2 in the
setting mode. (To set the unit, see 8.2.6 " Normal Indicating Unit ")
Displayed in the unit set by UNIT 1
In the case of total count display,
“C” appears while counting is in
progress.
Displayed in the unit set by UNIT 2
While communication is in
progress, “ ” appears.
Measured value display format
(1) Flow velocity value and instantaneous flow rate display
4 significant digits (for the span flow rate)
- 1 0 . 0 0 m l / s
Time unit
Flow
unit
Numeric value is indicated in 7 digits including a
decimal point. (Up to 9999999)
Flow direction: Forward direction “ ” (blank)
Reverse direction “
− ”