A/D CONVERTER
2-9
ADC Control Register (Continued)
ADCCON (0x000)
Access: Read/Write
MODESEL
ADC Mode Selection Field
00 = 3-point simultaneous sampling
01 = 1-point sampling
10 = 2-point simultaneous sampling
ADC Input Selection Field for SHA1
0000 = AIN0
0101 = AIN5
1010 = AIN10
0001 = AIN1
0110 = AIN6
1011 = AIN11
0010 = AIN2
0111 = AIN7
1100 = AIN12
0011 = AIN3
1000 = AIN8
1101 = AIN13
SHA1SEL
0100 = AIN4
1001 = AIN9
1110 = AIN14
ADC Input Selection Field for SHA2
0000 = AIN0
0101 = AIN5
1010 = AIN10
0001 = AIN1
0110 = AIN6
1011 = AIN11
0010 = AIN2
0111 = AIN7
1100 = AIN12
0011 = AIN3
1000 = AIN8
1101 = AIN13
SHA2SEL
0100 = AIN4
1001 = AIN9
1110 = AIN14
ADC Input Selection Field for SHA3
0000 = AIN0
0101 = AIN5
1010 = AIN10
0001 = AIN1
0110 = AIN6
1011 = AIN11
0010 = AIN2
0111 = AIN7
1100 = AIN12
0011 = AIN3
1000 = AIN8
1101 = AIN13
SHA3SEL
0100 = AIN4
1001 = AIN9
1110 = AIN14
NOTE
After ADC block is enabled (ADCEN==1), 40us stabilization time must be needed.