Inverter motor status register – Samsung S3F401F User Manual
Page 113

INVERTER MOTOR CONTROLLER (IMC)
S3F401F_UM_REV1.00
6-34
Inverter Motor Status Register
IMSTATUS (0x008)
Access: Read/Write
31 30 29 28 27 26 25 24
−
−
−
−
−
−
−
−
R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0
23 22 21 20 19 18 17 16
−
−
−
−
−
−
−
−
R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0
15 14 13 12 11 10 9 8
−
−
−
−
−
−
−
−
R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0
7 6 5 4 3 2 1 0
−
−
−
−
−
−
UPDOWNSTAT
FAULTSTAT
R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0
W: Write
R: Read
-0: 0 After reset
-1: 1 After reset
-U: Undefined after reset
FAULTSTAT
Status of PWM Output Signal
0 = Normal operating
1 = High-Z (Inverter motor block is operating but the status of PWM signal is High-Z.
This bit can be set by fault detection of PWMxOFF pin or IMCON0.14.)
Note: If this bit is written to 0 and IMCON0.14 is 0, inverter motor control signal is output to PWM output.
UPDOWNSTAT Status of PWM Counter
0 = Up counting
Æ This bit is always ‘0’ in the saw-tooth mode.
1 = Down counting