1 performance features – Siemens Simatic S7-400 User Manual
Page 430
CPUs for M7-400
11-2
S7-400, M7-400 Programmable Controllers Module Specifications
A5E00069467-07
11.1
Performance Features
Introduction
There are two CPUs with different clock frequencies available for use with the
automation computer.
Table 11-1 gives you an overview of the most important performance features of
these CPUs.
Table 11-1 Performance Features of the CPUs
Performance Features
CPU 486-3
(6ES7486-3AA00-0AB0)
CPU 488-3
(6ES7488-3AA00-0AB0)
Processor
Pentium 75 MHz
Pentium 120 MHz
MEM 478 DRAM memory submodules*
for main memory
•
Expansion capability
•
Supply voltage
16 Mbytes
3.3 V
16 Mbytes
3.3 V
Second-level cache
No
250 Kbytes
Submodule receptacle for memory card
Yes
Submodule receptacles for interface
submodules
2
Connection of expansions
Max. 3
MPI
Yes
Watchdog *
Yes
* see M7-SYS User Manual