[:SOURce]:IQ:TRIGger:DURation
Syntax
[:SOURce]:IQ:TRIGger:DURation
[:SOURce]:IQ:TRIGger:DURation?
Description
Set the duration of the single trigger signal.
Query the duration of the single trigger signal.
Parameter
Name
Type
Range
Default
Integer
1 to 65535
1
Explanation
This command is valid only when selecting "Single" operation mode.
describes the number of points (
r
N
). The actual time (
r
T
) can be obtained
according to the current sample rate (
a
S
):
a
r
r
S
N
T
=
.
After the duration is set, you can use the up/down direction keys or knob to
modify the duration at the current step. You can query or set the current step
[:SOURce]:IQ:TRIGger:DURation:STEP
command.
Return Format
The query returns the duration of the single output signal, for example, 4000.
Example
:IQ:TRIG:DUR 4000
:IQ:TRIG:DUR?
Related
Commands
[:SOURce]:IQ:TRIGger:DURation:STEP
[:SOURce]:IQ:TRIGger:OPTMode
[:SOURce]:IQ:TRIGger:DURation:STEP
Syntax
[:SOURce]:IQ:TRIGger:DURation:STEP
[:SOURce]:IQ:TRIGger:DURation:STEP?
Description
Set the duration step.
Query the duration step.
Parameter
Name
Type
Range
Default
Integer
1 to 10000
1
Explanation
After setting the duration step, you can use the up/down direction keys or knob to
modify the duration at the current step. At this point, you can query or reset the
Return Format
The query returns the duration step, for example, 500.
Example
:IQ:TRIG:DUR:STEP 500
:IQ:TRIG:DUR:STEP?
Related
Command