Source]:am:waveform, Source]:correction command subsystem, Source]:correction:flatness:count – RIGOL DSG3000 Series User Manual
Page 39: Source]:correction command subsystem -19

RIGOL
DSG3000 Programming Guide
2-19
[:SOURce]:AM:WAVEform
Syntax
[:SOURce]:AM:WAVEform SINE|SQUA
[:SOURce]:AM:WAVEform?
Description
Select the AM modulation waveform.
Query the AM modulation waveform.
Parameter
Name
Type
Range
Default
SINE|SQUA
Discrete
SINE|SQUA
SINE
Explanation
The parameter "SINE|SQUA" can set the AM modulation waveform to "Sine" or
"Square".
When "Ext" modulation source is selected, this command is invalid.
Return Format
The query returns SINE or SQUA.
Example
:AM:WAVE SQUA
:AM:WAVE?
Related
Command
[:SOURce]:CORRection Command Subsystem
Command List:
[:SOURce]:CORRection:FLATness:COUNt
[:SOURce]:CORRection:FLATness:DELete
[:SOURce]:CORRection:FLATness:LIST
[:SOURce]:CORRection:FLATness:PAIR
[:SOURce]:CORRection:FLATness[:STATe]
[:SOURce]:CORRection:FLATness:COUNt
Syntax
[:SOURce]:CORRection:FLATness:COUNt?
Description
Query the number of points of the current flatness correction table.
Explanation
[:SOURce]:CORRection:FLATness:DELete
number of points in the table or the
[:SOURce]:CORRection:FLATness:PAIR
command to increase the number of points in the table.
Return Format
The query returns the number of points in the flatness table in integer. For example,
5.
Related
Commands
[:SOURce]:CORRection:FLATness:DELete
[:SOURce]:CORRection:FLATness:PAIR