Source]:sweep:list:initialize:fstep, Source]:sweep:list:initialize:preset – RIGOL DSG3000 Series User Manual
Page 105

RIGOL
DSG3000 Programming Guide
2-85
[:SOURce]:SWEep:LIST:INITialize:FSTep
Syntax
[:SOURce]:SWEep:LIST:INITialize:FSTep
Description
Recalculate the data point set in the current step sweep to generate a new sweep list.
Explanation
In the new sweep list, "ListNum" depends on the "Points" of the step sweep.
"Frequency" depends on the "Start Frequency" and "Stop Frequency" of the step
sweep.
"Amplitude" depends on the "start Level" and "Stop Level" of the step sweep.
"Time" depends on the "Dwell Time" of the step sweep.
Related
Commands
[:SOURce]:SWEep:STEP:DWELl
[:SOURce]:SWEep:STEP:POINts
[:SOURce]:SWEep:STEP:STARt:FREQuency
[:SOURce]:SWEep:STEP:STARt:LEVel
[:SOURce]:SWEep:STEP:STOP:FREQuency
[:SOURce]:SWEep:STEP:STOP:LEVel
[:SOURce]:SWEep:LIST:INITialize:PRESet
Syntax
[:SOURce]:SWEep:LIST:INITialize:PRESet
Description
Reset the sweep list to factory setting.
Explanation
After resetting the sweep list using this command, the sweep list only contains
one frequency point (6GHz) and level point (-140dBm).
commands to re-edit the current sweep list.
Related
Commands
[:SOURce]:SWEep:LIST:ADDList
[:SOURce]:SWEep:LIST:DELete