Source]:iq:baseout:level, Source]:iq:baseout:level:step – RIGOL DSG3000 Series User Manual
Page 51

RIGOL
DSG3000 Programming Guide
2-31
[:SOURce]:IQ:BASeout:LEVel
Syntax
[:SOURce]:IQ:BASeout:LEVel
[:SOURce]:IQ:BASeout:LEVel?
Description
Set the baseband output amplitude.
Query the baseband output amplitude.
Parameter
Name
Type
Range
Default
Real
0V to 1.5V
1V
Explanation
When
can also be set in "Number + Unit" form, for example, 1.1V.
The default unit of the return value is V.
After the baseband output amplitude is set, you can use the up/down direction
keys or knob to modify the amplitude at the current step. You can query or set
[:SOURce]:IQ:BASeout:LEVel:STEP
command.
Return Format
The query returns the amplitude of the baseband output signal, for example,
1.100000.
Example
:IQ:BAS:LEV 1.1
:IQ:BAS:LEV?
Related
Command
[:SOURce]:IQ:BASeout:LEVel:STEP
[:SOURce]:IQ:BASeout:LEVel:STEP
Syntax
[:SOURce]:IQ:BASeout:LEVel:STEP
[:SOURce]:IQ:BASeout:LEVel:STEP?
Description
Set the baseband output amplitude step.
Query the baseband output amplitude step.
Parameter
Name
Type
Range
Default
Real
0.1V to 0.5V
0.1V
Explanation
When
can also be set in "Number + Unit" form, for example, 0.2V.
The default unit of the return value is V.
After setting the baseband output amplitude step, you can use the up/down
direction keys or knob to modify the output amplitude at the current step. At this
point, you can query or reset the output amplitude using the
Return Format
The query returns the baseband output amplitude step, for example, 0.200000.
Example
:IQ:BAS:LEV:STEP 0.2
:IQ:BAS:LEV:STEP?
Related
Command