AMETEK BPS Series Programming Manual User Manual
Page 99
BPS / MX / RS Series SCPI Programming Manual
AMETEK Programmable Power
Manual P/N 7003-961 Rev. AA
99
4.19
Source Subsystem - Phase
This subsystem programs the output phase angle of the AC/DC source. When the phase
command is used to program a single-phase unit, the only discernible effect is to cause an
instantaneous shift in the output waveform phase relative to an external reference signal.
Subsystem Syntax
[SOURce:]
PHASe
[:IMMediate]
Sets the output phase
PHASe
Phase Selectable
This commands sets the phase of the output voltage waveform relative to an external
reference for single-phase power source. Phase B and C in a three phase system are
programmed relative to phase A. The phase angle is programmed in degrees. Positive
phase angles are used to program the leading phase, negative phase angles are used to
program the lagging phase.
Command Syntax
[SOURce:]PHASe[:IMMediate]
Parameters
-360 through +360
*RST Value
Define by the PONSetup:PHASe
Examples PHAS
45
Query Syntax
[SOURce:]PHASe?
Returned Parameters