AMETEK BPS Series Programming Manual User Manual
Page 92

AMETEK Programmable Power
BPS / MX / RS Series SCPI Programming Manual
92
Manual P/N 7003-961 Rev AA
4.17.3
List - Frequency
LIST:FREQuency
This command sets the sequence of frequency list points. The frequency points are given in
the command parameters, which are separated by commas. The order in which the points
are entered determines the sequence in which they are output when a list is triggered.
Command Syntax
[SOURce:]LIST:FREQuency[:LEVel]
Parameters
Values limited to the frequency range
Unit HZ
(Hertz)
Examples LIST:FREQ
60,65,70
Query Syntax
[SOURce:]LIST:FREQ?
Returned Parameters
Related Commands
LIST:FREQ:POIN?
LIST:COUN
LIST:DWEL
LIST:STEP LIST:FREQ:SLEW
LIST:FREQuency:POINts?
This query returns the number of points specified in LIST:FREQuency. Note that it returns
only the total number of points, not the point values.
Query Syntax
[SOURce:]LIST:FREQ[:LEVel]:POINts?
Returned Parameters
Example LIST:FREQ:POIN?
Related Commands
LIST:FREQ
LIST:FREQuency:SLEW
This command sets the sequence of frequency slew list points. The frequency points are
given in the command parameters, which are separated by commas.The order in which the
points are entered determines the sequence in which they are output when a list is triggered.
Command Syntax
[SOURce:]LIST:FREQuency:SLEW
Parameters
0.01 to 1E9
⏐MAXimum
Unit
HZ (Hertz) per second
Examples
LIST:FREQ:SLEW 10, 1E2, MAX
Query Syntax
[SOURce:]LIST:FREQ:SLEW?
Returned Parameters
Related Commands
LIST:FREQ:SLEW:POIN?
LIST:COUN
LIST:DWEL LIST:STEP LIST:FREQ
LIST:FREQuency:SLEW:POINts?
This query returns the number of points specified in LIST:FREQuency:SLEW. Note that it
returns only the total number of points, not the point values.
Query Syntax
[SOURce:]LIST:FREQ:SLEW:POINts?
Returned Parameters
Example LIST:FREQ:SLEW:POIN?
Related Commands
LIST:FREQ:SLEW