AMETEK BPS Series Programming Manual User Manual
Page 81

BPS / MX / RS Series SCPI Programming Manual
AMETEK Programmable Power
Manual P/N 7003-961 Rev. AA
81
4.13
Source Subsystem - Frequency
This subsystem programs the output frequency of the AC/DC source.
Subsystem Syntax
[SOURce:]
FREQuency
:IMMediate]
Sets the frequency
:MODE
Sets frequency mode
(FIX|STEP|PULS|LIST|SENS|EXT)
:SLEW
[:IMMediate]
Sets the frequency slew rate
:MODE
Sets frequency slew mode
(FIX|STEP|PULS|LIST)
:TRIGgered
|
MAXimum Sets the triggered frequency slew rate
:TRIGgered
Sets the triggered frequency
FREQuency
This command sets the frequency of the output waveform.
Command Syntax
[SOURce:]FREQuency[:CW|:IMMediate]
Parameters
Refer to specifications table in User Guide
Unit Hz
(Hertz)
*RST Value
60 Hz
Examples FREQ
50
Query Syntax
[SOURce:]FREQuency?
Returned Parameters
Related Commands
FREQ:MODE FREQ:SLEW
FREQuency:MODE
This command determines how the output frequency is controlled. The choices are:
FIXed
The output frequency is unaffected by a triggered output transient.
STEP
The output frequency is programmed to the value set by
FREQuency:TRIGgered when a triggered transient occurs.
PULSe
The output frequency is changed to the value set by
FREQuency:TRIGgered for a duration determined by the pulse commands.
LIST
The output frequency is controlled by the frequency list when a triggered
transient occurs.
SENSe
Selects external sync mode.
EXTernal
Selects external clock input.
Command Syntax
[SOURce:]FREQuency:MODE
Parameters
FIXed | STEP | PULSe | LIST|SENSe|EXT
*RST Value
FIXed
Examples FREQ:MODE
FIX
Query Syntax
[SOURce:]FREQuency:MODE?
Returned Parameters
Related Commands
FREQ FREQ:TRIG