AMETEK Programmable Power

BPS / MX / RS Series SCPI Programming Manual

176

Manual P/N 7003-961 Rev AA

IEC411:VARiants:HOLD:TIME

This command will set the variant hold time in seconds. Refer to Figure 9-13 in the User
Manual.

Command Syntax

IEC411:VARiants: HOLD:TIME

Parameters

Examples

IEC411:VAR: HOLD:TIME 0.5

Query Syntax

IEC411:VAR: HOLD:TIME?

Returned Parameters

IEC411:VARiants:HOLD:VOLTage[:PERCent]

This command will set the variant level as a percentage of the nominal volts for the duration
of the hold time.

Command Syntax

IEC411:VARiants:HOLD:VOLTage[:PERCent]

Parameters

Examples

IEC411:VAR: HOLD:VOLT 70

Query Syntax

IEC411:VAR: HOLD:VOLT?

Returned Parameters

IEC411:VARiants:FALL[:TIME]

This command will set the variant fall time in seconds. Refer to Figure 9-13 in the User
Manual.

Command Syntax

IEC411:VARiants:FALL[:TIME]

Parameters

Examples

IEC411:VAR:FALL 0.5

Query Syntax

IEC411:VAR:FALL?

Returned Parameters

IEC411:VARiants:RISE[:TIME}

This command will set the variant rise time in seconds. Refer to Figure 9-13 in the User
Manual.

Command Syntax

IEC411:VARiants:RISE:TIME

Parameters

Examples IEC411:VAR:RISE:TIME

0.25

Query Syntax

IEC411:VAR:RISE:TIME?

Returned Parameters