BPS / MX / RS Series SCPI Programming Manual
AMETEK Programmable Power
Manual P/N 7003-961 Rev. AA
191
DO160:NORMal:VOLT_FREQ:MINimum
This command will set the voltage and frequency to the minimum level for the normal
operation.
Command Syntax
DO160:NORMal:VOLT_FREQ:MINimum
Parameters none
Examples DO160:NORM:VOLT_FREQ:MIN
Query Syntax
none
DO160:NORMal:VOLT_FREQ:MAXimum
This command will set the voltage and frequency to the maximum level for the normal
operation.
Command Syntax
DO160:NORMal:VOLT_FREQ: MAXimum
Parameters none
Examples DO160:NORM:VOLT_FREQ:MAX
Query Syntax
none
DO160:NORMal:VOLTage:UNBalance
This command will unbalance the voltage level for each phase to the normal high and low
operating voltage of each phase. This test is valid only for three phase AC source.
Command Syntax
DO160:NORMal:VOLTage:UNBalance
Parameters none
Examples DO160:NORM:VOLT:UNB
Query Syntax
none
DO160:NORMal:WAVeform:DISTortion
This command will set the voltage distortion to 5% for the duration of the test.
Command Syntax
DO160:NORMal:WAVeform:DISTortion
Parameters none
Examples DO160:NORM:WAV:DIST
Query Syntax
none