DO160:NORMal:VOLT_FREQ:MINimum

This command will set the voltage and frequency to the minimum level for the normal
operation.

Command Syntax

DO160:NORMal:VOLT_FREQ:MINimum

Parameters none
Examples DO160:NORM:VOLT_FREQ:MIN
Query Syntax

none

DO160:NORMal:VOLT_FREQ:MAXimum

This command will set the voltage and frequency to the maximum level for the normal
operation.

Command Syntax

DO160:NORMal:VOLT_FREQ: MAXimum

Parameters none
Examples DO160:NORM:VOLT_FREQ:MAX
Query Syntax

none

DO160:NORMal:VOLTage:UNBalance

This command will unbalance the voltage level for each phase to the normal high and low
operating voltage of each phase. This test is valid only for three phase AC source.

Command Syntax

DO160:NORMal:VOLTage:UNBalance

Parameters none
Examples DO160:NORM:VOLT:UNB
Query Syntax

none

DO160:NORMal:WAVeform:DISTortion

This command will set the voltage distortion to 5% for the duration of the test.

Command Syntax

DO160:NORMal:WAVeform:DISTortion

Parameters none
Examples DO160:NORM:WAV:DIST
Query Syntax

none