BPS / MX / RS Series SCPI Programming Manual
AMETEK Programmable Power
Manual P/N 7003-961 Rev. AA
87
Command Syntax
[SOURce:]LIMit:VOLTage
Parameters
voltage ranges
[command protected]
Query Syntax
[SOURce:]LIMit:VOLTage?
Returned Parameters
Example: LIM:VOLT?
Response = 150.0,300.0,400.0
This MX unit has a 150 V low range, a 300 V high range and is
equipped with the optional -HV option. (400 V range).
LIMit:PHASe
This command will configure the power source controller for the number of output phases. A
value of zero will configure the source as a single-phase unit. A value of 120° will configure
the power source controller as a three phase unit with a 120° phase offset between phase
A, B and C. Any other value will configure the controller as a two phase unit using phase A
and C.
Command Syntax
[SOURce:]LIMit:PHASe
Parameters
0 to 360
[command protected]
Query Syntax
[SOURce:]LIMit:PHASe?
Returned Parameters