BPS / MX / RS Series SCPI Programming Manual
AMETEK Programmable Power
Manual P/N 7003-961 Rev. AA
119
Command Syntax
SYSTem:LOCal
Parameters None
Example SYST:LOC
Related Commands
SYST:REM
SYSTem:REMote
This command can only be used with the RS-232 interface. It sets the interface in the
Remote state, which disables all front panel controls.
Command Syntax
SYSTem:REMote
Parameters None
Example SYST:REM
Related Commands
SYST:LOC
SYSTem:CONFigure[:BYTE]
This command will set the system configuration. This is a protected command and requires
a password. The query response is available however. Available options are returned
separated by a comma. The last field is the MX System Configuration setting. (MX15 and
MX45
1
through MX270). For a list of available parameters, refer to the *OPT? command
section in this manual.
Command Syntax
SYSTem:CONFigure
Parameters
2
SCPI,NOUT,ADV,
CLK/LOC,DO160,MIL704D,IEC411,IEC413,ABD,LF,MX45
Example SYST:CONF
SCPI,IEC411
SYST:CONF?
Returned Parameters
Related Commands
*OPT?
1
Note: MX30-3Pi configuration is reported as MX45 on Series I MX. If firmware revision is less than 1.11, there
is no system field in the syst:conf? query response.
2
Note: SYST:CONF parameter list will not have “LF” field if firmware revision is 1.13 or lower.