beautypg.com

AMETEK BPS Series Programming Manual User Manual

Page 104

background image

AMETEK Programmable Power

BPS / MX / RS Series SCPI Programming Manual

104

Manual P/N 7003-961 Rev AA

4.21

Source Subsystem - Pulse

This subsystem controls the generation of output pulses. The PULSe:DCYCle,
PULSe:PERiod, and PULSe:WIDTh commands are coupled, which means that the values
programmed by any one of these commands can be affected by the settings of the others.
Refer to Table 4-1 and Table 4-2 under PULSe:HOLD for an explanation of how these
commands affect each other.

Subsystem Syntax

[SOURce:]
PULSe

:COUNt | MAXimum

Selects transient pulse count

:DCYCle

Selects pulse duty cycle

:PERiod

Selects pulse period when the count is greater than
1

:WIDTh

Selects width of the pulses

:HOLD WIDTh|DCYCle

Select which parameter to hold during programming

PULSe:COUNt

This command sets the number of pulses that are output when a triggered output transient
occurs. The command accepts parameters in the range 1 through 2E8. If MAXimum is sent,
the output pulse repeats indefinitely.

Command Syntax

[SOURce:]PULSe:COUNt

Parameters

1 to 2E8 | MINimum | MAXimum

*RST Value

1

Examples PULS:COUN

3

PULS:COUN MIN

PULS:COUN MAX

Query Syntax

[SOURce:]PULS:COUNt?

Returned Parameters

Related Commands

PULS:DCYC

PULS:PER

PULS:WIDT

PULSe:HOLD

This command specifies whether the pulse width or the duty cycle is to be held constant
when the pulse period changes. The following tables describe how the duty cycle, period,
and width are affected when one parameter is set in a single program message. if two or
three parameters are set in a single message, there sequence will define how they will be
affected.

Command Syntax

[SOURce:]PULSe:HOLD

Parameters WIDTh|DCYCle
*RST Value

WIDTh

Examples PULS:HOLD

DCYC

Query Syntax

[SOURce:]PULSe:HOLD?

Returned Parameters

Related Commands

PULS:COUN PULS:DCYC PULS:PER PULS:WIDT