beautypg.com

AMETEK BPS Series Programming Manual User Manual

Page 157

background image

BPS / MX / RS Series SCPI Programming Manual

AMETEK Programmable Power

Manual P/N 7003-961 Rev. AA

157

6.6.1

Voltage and Current Measurements

To the rms voltage or current, use:

MEASure:VOLTage?or

MEASure:CURRent?

To measure the dc voltage or current, use:

MEASure:VOLTage:DC?or

MEASure:CURRent:DC?

To measure the maximum current amplitude and the current crest factor, use:

MEASure:CURRent:AMPLitude:MAXimum?

MEASure:CURRent:CREStfactor?

To reset the peak measuremnt , use

MEAS:CURR:AMPL:RESet

6.6.2

Power Measurements

The MEASure queries can return real, and apparent power measurements as well as dc
power and power factor using the following commands:

MEASure:POWer:AC:APParent?

measures the AC component of apparent
power in VA

MEASure:POWer:AC:REAL?

measures the in-phase component of
power in watts

MEASure:POWer:AC:PFACtor?

returns the output power factor

MEASure:POWer:DC?

measures the dc component of power

6.6.3

Frequency Measurements

To measure the frequency, use the following command:

MEASure:FREQuency?