AMETEK BPS Series Programming Manual User Manual
Page 182

AMETEK Programmable Power
BPS / MX / RS Series SCPI Programming Manual
182
Manual P/N 7003-961 Rev AA
Command Syntax
IEC413:FCURve:PAUSe
Parameters
Examples IEC413:FCURve:PAUS
2
Query Syntax
IEC413:FCURve:PAUS?
Returned Parameters
IEC413:OSWing:LEVel
This command will set the level for the ‘over swing’ harmonics combination test. The
command has two parameters, one for the third and one for the fifth order harmonic. The
IEC413:STATe must be in the off position and the user class must be selected to accept the
command.
Command Syntax
IEC413:OSWing:LEVel
Parameters
0 to 20%
Examples IEC413:OSWing:LEVel
10
Query Syntax
IEC413:OSWing:LEVel?
Returned Parameters
IEC413:OSWing:DWELl
This command will set the dwell time in seconds for the over swing harmonics combination
test. The class must be selected prior to this command. Query with min and max to find the
range of the dwell time.
Command Syntax
IEC413OSWing:DWELl
Parameters
Examples IEC413:OSWing:DWEL
10
Query Syntax
IEC413:OSWing:DWEL?
Returned Parameters
IEC413:OSWing:PAUSe
This command will set the pause time in seconds. This is the time between tests when
RUN:ALL is selected. The class must be selected prior to this command. Query with min
and max to find the range of the pause time.
Command Syntax
IEC413:OSWing:PAUSe
Parameters
Examples IEC413:OSWing:PAUS
2
Query Syntax
IEC413:OSWing:PAUS?
Returned Parameters