AMETEK BPS Series Programming Manual User Manual
Page 112

AMETEK Programmable Power
BPS / MX / RS Series SCPI Programming Manual
112
Manual P/N 7003-961 Rev AA
VOLTage:SLEW:MODE
Phase Selectable
This command determines how the output voltage slew rate is controlled during a triggered
output transient. The choices are:
FIXed
The slew rate is unaffected by a triggered output transient.
STEP
The slew rate is programmed to the value set by
VOLTage:SLEW:TRIGgered when a triggered transient occurs.
PULSe
The slew rate is changed to the value set by VOLTage:SLEW:TRIGgered
for a duration determined by the pulse commands.
LIST
The slew rate is controlled by the voltage slew list when a triggered transient
occurs.
Command Syntax
[SOURce:]VOLTage:SLEW:MODE
Parameters
FIXed | STEP | PULSe | LIST
*RST Value
FIX
Examples
VOLT:SLEW:MODE LIST
VOLT:SLEW:MODE FIX
Query Syntax
[SOURce:]VOLTage:SLEW:MODE?
Returned Parameters
Related Commands
VOLT:SLEW:TRG
VOLT:SLEW
VOLTage:SLEW:TRIGgered
Phase Selectable
This command selects the slew rate that will be set during a triggered step or pulse
transient. A parameter of MAXimum will set the slew to its maximum possible rate. The
maximum allowed value is1E9.
Command Syntax
[SOURce:]VOLTage:SLEW:TRIGgered
Parameters
0 to 1E9 | MAXimum
Unit
V/S (volts per second)
*RST Value
MAXimum
Examples
VOLT:SLEW:TRIG 1
VOLT:SLEW:TRIG MAX
Query Syntax
[SOURce:]VOLTage:SLEW:TRIGgered?
Returned Parameters
Related Commands
VOLT:SLEW:MODE
VOLT:SLEW