[:FSCale]

Calibrate

full-scale

AC

voltage

measurements

at

higher temperature

:DC

[:FSCale]

Calibrate

full-scale

AC

voltage

measurements

:ZERO

Cancel

AC

voltage

measurements

offset

[:SOURce]
:PHASe

Calibrate

output

phase

angle relative to external sync.

:VOLTage

[:AC]

:LRANge

[:FSCale]

Calibrate full-scale output voltage at low voltage
range

:ZERO

Trim output voltage offset at low voltage range.

:HFRequency

Calibrate full scale output voltage at low voltage
range and high frequency.

:HRANge

[:FSCale]

Calibrate full-scale output voltage at high voltage
range

:ZERO

Trim output voltage offset at high voltage range.

:HFRequency

Calibrate full scale output voltage at high voltage
range and high frequency.

:DC

:LRANge

[:FSCale]

Calibrate full-scale output dc voltage at low voltage
range.

:ZERO

Trim output dc voltage offset at low voltage range.

:HRANge

[:FSCale]

Calibrate full-scale output dc voltage at high voltage
range. (positive DC)

:ZERO

Trim output dc voltage offset at high voltage range.

:IMPedance

:REAL

[:FSCale]

Calibrate the real part of the programmable output
impedance at full-scale value

:ZERO

Calibrate the real part of the programmable output
impedance at minimum value

:REACtive

[:FSCale]

Calibrate the reactive part of the programmable
output impedance at full-scale value

:ZERO

Calibrate the reactive part of the programmable
output impedance at minimum value

:IHARmonic?

IEC413

interharmonic