AMETEK BPS Series Programming Manual User Manual
Page 40

AMETEK Programmable Power
BPS / MX / RS Series SCPI Programming Manual
40
Manual P/N 7003-961 Rev AA
[:FSCale]
Calibrate
full-scale
AC
voltage
measurements
at
higher temperature
:DC
[:FSCale]
Calibrate
full-scale
AC
voltage
measurements
:ZERO
Cancel
AC
voltage
measurements
offset
[:SOURce]
:PHASe
Calibrate
output
phase
angle relative to external sync.
:VOLTage
[:AC]
:LRANge
[:FSCale]
Calibrate full-scale output voltage at low voltage
range
:ZERO
Trim output voltage offset at low voltage range.
:HFRequency
Calibrate full scale output voltage at low voltage
range and high frequency.
:HRANge
[:FSCale]
Calibrate full-scale output voltage at high voltage
range
:ZERO
Trim output voltage offset at high voltage range.
:HFRequency
Calibrate full scale output voltage at high voltage
range and high frequency.
:DC
:LRANge
[:FSCale]
Calibrate full-scale output dc voltage at low voltage
range.
:ZERO
Trim output dc voltage offset at low voltage range.
:HRANge
[:FSCale]
Calibrate full-scale output dc voltage at high voltage
range. (positive DC)
:ZERO
Trim output dc voltage offset at high voltage range.
:IMPedance
:REAL
[:FSCale]
Calibrate the real part of the programmable output
impedance at full-scale value
:ZERO
Calibrate the real part of the programmable output
impedance at minimum value
:REACtive
[:FSCale]
Calibrate the reactive part of the programmable
output impedance at full-scale value
:ZERO
Calibrate the reactive part of the programmable
output impedance at minimum value
:IHARmonic?
IEC413
interharmonic