beautypg.com

AMETEK BPS Series Programming Manual User Manual

Page 69

background image

BPS / MX / RS Series SCPI Programming Manual

AMETEK Programmable Power

Manual P/N 7003-961 Rev. AA

69

MEASure:POWer:AC:PFACtor?
FETCh:POWer[:AC]:PFACtor?

Phase Selectable

This query returns the output power factor. The power factor is computed as:

power factor = real power / apparent power

Query Syntax

MEASure[:SCALar]:POWer[:AC]:PFACtor?

Parameters None
Examples MEAS:POW:PFAC?

Returned Parameters

Related Commands

INST:NSEL

MEASure:POWer:DC?
FETCh:POWer:DC?

Phase Selectable

This query returns the DC component of the power being sourced at the output terminals in
kilo watts (KW). The query should be used only when the voltage mode is set for DC or an
error message will be generated.

Query Syntax

MEASure[:SCALar]:POWer:DC?

Parameters None
Examples MEAS:POW?

Returned Parameters

Related Commands

INST:NSEL