beautypg.com

AMETEK BPS Series Programming Manual User Manual

Page 195

background image

BPS / MX / RS Series SCPI Programming Manual

AMETEK Programmable Power

Manual P/N 7003-961 Rev. AA

195

DO160:ABNormal:VOLTage:OVER

This command will set the voltage to the surge level for the abnormal operation.

Command Syntax

DO160:ABNormal:VOLTage:OVER

Parameters none
Examples DO160:ABN:VOLT:OVER
Query Syntax

none

DO160:ABNormal:VOLTage:DC:LOW

This command will set the voltage to low voltage test for the abnormal operation. Refer to
Section 9.1 of the User Manual.

Command Syntax

DO160:ABNormal:VOLTage:DC:LOW

Parameters none
Examples DO160:ABN:VOLT:DC:LOW
Query Syntax

none

DO160:ABNormal:FREQuency:TRANsient

This command applies to Group 1 only for the Eurocae standard. Refer to Table 12 in the
User Manual.

Command Syntax

DO160:ABNormal:FREQuency:TRANsient

Parameters none
Examples DO160:ABN:FREQ:TRAN
Query Syntax

none

Returned Parameters

none

DO160:CATegory

This command will select the proper equipment category in DC mode only. It has no effect
in AC mode.

Command Syntax

DO160:CATegory

Parameters
Examples DO160:CAT

B

Query Syntax

DO160:CAT?