4.9
Power Measurement Subsystem
This subsystem programs the power measurement capability of the MX/RS/BPS Series
source.
Subsystem Syntax
MEASure | FETCh
[:SCALar]
:POWer
[:AC]
[:REAL]?
Returns
real
power
:APParent?
Returns
VA
PFACtor?
Returns
power
factor
:DC
Return the dc component of power measurement
MEASure:POWer[:AC]?
FETCh:POWer[:AC]?
Phase Selectable
This query returns the in-phase component of power being sourced at the output terminals
in kilo watts (KW).
Query Syntax
MEASure[:SCALar]:POWer[:AC][:REAL]?
Parameters None
Examples MEAS:POW:AC?
Returned Parameters
Related Commands
INST:NSEL
MEASure:POWer:AC:APParent?
FETCh:POWer[:AC]:APParent?
Phase Selectable
This query returns the apparent power being sourced at the output terminals in kilo volt-
amperes (KVA).
Query Syntax
MEASure[:SCALar]:POWer[:AC]:APParent?
Parameters None
Examples MEAS:POW:AC:APP?
Returned Parameters
Related Commands