BPS / MX / RS Series SCPI Programming Manual

AMETEK Programmable Power

Manual P/N 7003-961 Rev. AA

63

MEASure:CURRent:DC?
FETCh:CURRent:DC?

Phase Selectable

These queries return the dc component of the output current being sourced at the output
terminals. This command should be used when the voltage mode of the source is set for DC

Query Syntax

MEASure[:SCALar]:CURRent:DC?

FETCh[:SCALar]:CURRent:DC?
Parameters None
Examples MEAS:CURR?

FETC:CURR?

Returned Parameters

Related Commands

INST:NSEL

MEASure:CURRent:AMPLitude:MAXimum?
FETCh:CURRent:AMPLitude:MAXimum?

Phase Selectable

These queries return and hold the absolute value of the peak current as sampled over one
measurement acquisition of 4096 data points. The returned value will be updated only when
a larger value is found. To update the value with every measurement a peak current reset
command should be used prior to the peak measurements.

Query Syntax

MEASure[:SCALar]:CURRent:AMPLitude:MAXimum?

FETCh[:SCALar]:CURRent:AMPLitude:MAXimum?
Parameters None
Examples MEAS:CURR:AMPL:MAX?

FETC:CURR:AMPL:MAX?

Returned Parameters

Related Commands

INST:NSEL

MEAS:CURR:AMPL:RESet

MEASure:CURRent:AMPLitude:RESet

Phase Selectable

This command will reset the peak current measurement to zero.

Query Syntax

MEASure[:SCALar]:CURRent:AMPLitude:RESset.

Parameters None
Examples MEAS:CURR:AMPL:RES
Returned Parameters

None

Related Commands

MEAS:CURR:AMPL:MAX?