AMETEK Programmable Power

BPS / MX / RS Series SCPI Programming Manual

174

Manual P/N 7003-961 Rev AA

IEC411:DIPS:RUN[:ALL]

This command will cause the automated test sequence by the standard to run. Refer to
Table 13 in the User Manual.

Command Syntax

IEC411:DIPS:RUN[:ALL]

Parameters

Examples IEC411:DIPS:RUN
Query Syntax

none

Returned Parameters

IEC411:DIPS:RUN:SINGle

This command will run a single test once. The test is defined by the dip parameters voltage,
cycle and angle.

Command Syntax

IEC411:DIPS:RUN:SINGle

Parameters

Examples IEC411:DIPS:RUN:SING
Query Syntax

none

Returned Parameters

IEC411:DIPS:VOLTage[:PERCent]

This command defines the dip voltage as a percentage of the nominal voltage when the run
single command is used.

Command Syntax

IEC411:DIPS:VOLTage[:PERCent]

Parameters

Examples IEC411:DIPS:VOLT

20

Query Syntax

IEC411:DIPS:VOLT?

Returned Parameters

IEC411:DIPS:CYCLes

This command defines the duration of the dip voltage expressed in the number of cycles.

Command Syntax

IEC411:DIPS:CYCLes

Parameters

Examples IEC411:DIPS:VOLT

20

Query Syntax

IEC411:DIPS:VOLT?

Returned Parameters