AMETEK BPS Series Programming Manual User Manual
Page 78

AMETEK Programmable Power
BPS / MX / RS Series SCPI Programming Manual
78
Manual P/N 7003-961 Rev AA
4.11.5
Programmable Impedance
[MX15-1Pi/MX30-3Pi/MX45-3Pi/RS Only]
OUTPut:IMPedance[:STATe] [MX15-1Pi
/
MX30-3Pi / MX45-3Pi / RS Series Only]
Phase Selectable
This command enables or disables the source output impedance programming. The state of
a disabled output impedance is equivalent to the minimum impedance. The query form
returns the output state.
Command Syntax
OUTPut:IMPdance[:STATe]
Parameters
0 | OFF | 1 | ON
*RST Value
OFF
Examples
OUTP:IMP 1
OUTP:IMP:STAT ON
Query Syntax
OUTPut:IMPdeance[:STATe]?
Returned Parameters
0 | 1
Related Commands
OUTPut:IMPedance:REAL
OUTput:IMPedance:REACtive
OUTPut:IMPedance:REAL
[MX15-1Pi / MX30-3Pi / MX45-3Pi / RS Series Only]
Phase Selectable
This command sets the real part of the output impedance of the AC source in mili-ohms.
OUTPut:IMPedance:STATe must be enabled for the programmed impedance to affect the
output.
Command Syntax
OUTP:IMPedance:REAL
Parameters
min to 200
*RST Value
min
Examples OUTP:IMP:REAL
200
Query Syntax
OUTPut:IMP:REAL?
Returned Parameters
Related Commands
OUTP:IMP
OUTP:IMP:REAC
OUTPut:IMPedance:REACtive [MX15-1Pi
/
MX30-3Pi / MX45-3Pi / RS Series Only]
Phase Selectable
This command sets the reactive part of the output impedance of the AC source in micro
Henry. OUTPut:IMPedance:STATe must be enabled for the programmed impedance to
affect the output.
Command Syntax
OUTP:IMP:REACtive
Parameters
min to 220 (uHenrys)
*RST Value
min
Examples OUTP:IMP:REAC
150
Query Syntax
OUTPut:IMP:REACtive?
Returned Parameters
Related Commands
OUTP:IMP
OUTP:IMP:REAL