beautypg.com

AMETEK BPS Series Programming Manual User Manual

Page 125

background image

BPS / MX / RS Series SCPI Programming Manual

AMETEK Programmable Power

Manual P/N 7003-961 Rev. AA

125

TRACe:CATalog

These commands return a list of defined waveform names. The list includes both pre-
defined waveforms such as SINusoid, SQUare, and CSINusoid, as well as any user-defined
waveforms.

Query Syntax:

TRACe:CATalog?

Returned Parameters

Example TRAC:CAT?
Related Commands

TRAC:DATA TRAC:DEL FUNC:SHAP

TRACe:DEFine

These commands define a new waveform with the name and allocates
storage for its data. The waveform name can then be referenced by the TRACe:DATA.

Note: The TRAC:DEF command causes waveform catalog data to be writing to the

Flash memory of the unit. This process requires about 500 msec to complete.
The TRACE:DATA command which normally follows should not be sent
during this period to allow this process to complete or the first part of the data
may be missed and an error will result.

Command Syntax:

TRACe:DEFine

Parameters
Example TRAC:DEF

flattop

Related Commands

TRAC:DATA TRAC:DEL FUNC:SHAP

TRACe:DELete

This command deletes the user-defined waveform table with the name
and makes its memory available for other waveforms.

Command Syntax:

TRACe:DELete[:NAME]

Parameters

name>

Example TRAC:DEL

flattop

Related Commands

TRAC:DATA TRAC:DEL FUNC:SHAP

TRACe:DELete

This command deletes ALL user-defined waveforms at once and makes all waveform
memory available for other waveforms. This command is only supported by firmware
revisions 0.16 and higher.

Command Syntax:

TRACe:DELete:ALL

Parameters

name>

Example TRAC:DEL:ALL
Related Commands

TRAC:DATA TRAC:DEL FUNC:SHAP