BPS / MX / RS Series SCPI Programming Manual
192
Manual P/N 7003-961 Rev AA
DO160:NORMal:VOLTage:MODulation
This command will cause output voltage modulation. The level of modulation is the function
of the rate of modulation. Refer to Figure 9-4 in the User Manual. The command parameter
is the rate of modulation in Hz.
Command Syntax
DO160:NORMal:VOLTage:MODulation
Parameters
Examples DO160:NORM:VOLT:MOD
20
Query Syntax
DO160:NORM:VOLT:MOD?
Returned Parameters
DO160:NORMal:VOLTage:INTerrupt
This command will cause output voltage interruption. There are 15 different levels of
interruption. Refer to Figure 9-6 in the User Manual for characteristic of each level.
Command Syntax
DO160:NORMal:VOLTage:INTerrupt
Parameters number> Examples DO160:NORM:VOLT:INT 4 Query Syntax DO160:NORM:VOLT:INT? Returned Parameters DO160:NORMal:VOLTage:SURG This command will generate the voltage levels required to generate a normal voltage VOLTAGE SURGE, for detail. Command Syntax DO160:NORMal:VOLTage:SURG Parameters none none DO160:NORMal:VOLTage:DC:UNDer This command will generate the voltage levels required to generate a normal voltage VOLTAGE UNDER, for detail. Command Syntax DO160:NORMal:VOLTage:DC:UNDer Parameters none
source. Refer to Section 9.1.4.1, under the heading titled
Examples DO160:NORM:VOLT:SURG
Query Syntax
source. Refer to Section 9.1 in the User Manual under the heading titled
Examples DO160:NORM:VOLT:DC:UND