BPS / MX / RS Series SCPI Programming Manual
AMETEK Programmable Power
Manual P/N 7003-961 Rev. AA
183
IEC413:SWEep:LEVel
This command will set the level for the harmonics sweep test. The command will accept
either one parameter or five parameters. In case of one parameter, the level will be set for
the selected range only. The IEC413:STATe must be in the off position and the user class is
selected to accept the command.
Command Syntax
IEC413:SWEep:LEVel
Parameters
0 to 20%
Examples IEC413:SWE:LEVel
10
Query Syntax
IEC413:SWE:LEVel?
Returned Parameters
IEC413:SWEep:DWELl
This command will set the dwell time in seconds for the entire sweep range. The class must
be selected prior to this command. Query with min and max to find the range of dwell time.
Command Syntax
IEC413:SWEep:DWELl
Parameters
Examples IEC413:SWE:DWEL
200
Query Syntax
IEC413:SWE:DWEL?
Returned Parameters
IEC413:SWEep:CURRent[:DATA]?
This command will return the measured harmonic current. This data is available after the
sweep is completed.
Command Syntax
IEC413:SWEep:CURRent[:DATA] ]?
Parameters none
Query Syntax
IEC413:SWE:CURR?
Returned Parameters
IEC413:SWEep:FREQuency[:DATA]?
This command will return the frequency data points that correspond to the harmonic current
data points. This data is available after the sweep is completed.
Command Syntax
IEC413:SWEep:FREQuency?
Parameters none
Query Syntax
IEC413:SWE:CURR:FREQ?
Returned Parameters